Our products as follows: 3kw ~ 3000kw/Outlet temperature:7ºC~ -85ºC/ The Details of the chiller: 2.Cooling Capacity Range: 1RT to 1000RT 3.52kw to 3520kw 12010Btu to 12010240Btu 3027.2Kal to 3027200Kal 3. The Refrigerant: R22/R407c/R410a/R404a/R134a/R507c. 4. We can also produce the chiller according to your requirements. One Parameter of our water chiller: Note: Winday Industrial is a professional R & D manufacturing and sales of industrial refrigeration equipment and refrigeration system design, installation service company. On behalf of product quality performance "efficient stability, progress energy efficiency." Equipment manufacturing process to achieve excellence, strict control, strict examination; Refrigeration program design to achieve repeated research, experiment, scrutiny, feasibility studies and other processes,and strive to provide customers with an optimized cooling system integration solutions and equipment. Steel Tool Box,Steel Truck Tool Box,Waterproof Steel Truck Tool Boxes,Steel Ute Tray Tool Box Foshan Tanghan Precision Metal Products Co., Ltd. , https://www.utetrayandcanopy.com
Research Laboratory Water Cooled Screw ChillerÂ
Air cooled,water cooled,screw type,scroll type,heat pump chiller, modular chiller.
1.The Temperature Range:7ºC to -85ºC. Â
One Parameter of our water chiller:
 Model
WD-
UNIT
188.1WSM3
220.1WSM3
235.1WSM3
260.1WSM3
260.1WSM3
290.1WSM3
335.1WSM3
372.1WSM3
400.1WSM3
445.1WSM3
Cooling capacity
Btu
641456.00
750640.00
801820.00
887120.00
955360.00
989480.00
1143020.00
1269264.00
1364800.00
1518340
RT
53.41
62.50
66.76
73.86
79.55
82.39
95.17
105.68
113.64
126.42
KÂ w
188.00
220.00
235.00
260.00
280.00
290.00
335.00
372.00
400.00
445.00
×104Kcal/h
16.00
19.00
20.00
22.00
24.00
25.00
29.00
32.00
34.00
38.00
Control mode
PLC automatic control
power source
380V/3N/50HZ
         Compressor
 Type
5-6 asymmetric semi-hermetic twin screw compressors
Startup type
Y-â–³
 Energy regulation
0-12.5%-25%-37.5%-50%-62.5%-75%-87.5%-100%
 Qty
1
Input power
KW
81.70
94.90
100.20
108.50
116.80
120.60
141.70
157.20
166.90
184.00
Operation Current
A
142.20
165.10
174.30
188.80
203.20
209.80
 246.60
273.50
290.40
320.20
Condenser
Type
High efficiency copper dry type shell-and-tube heat exchanger
 Water pipe connection
Â
DN100
DN125
DN150
 Cooling Water Flow
m³/h
61.30
71.50
76.20
83.70
90.20
93.30
108.30
120.20
128.80
142.90
Water pressure
kpa
58.00
58.00
65.00
70.00
70.00
71.00
71.00
72.00
72.00
72.00
   Evaporator
 Type
Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger
 Water pipe connection
Â
DN80
DN100
DN125
 Freezing water Flow
m³/h
40.00
47.50
50.00
55.00
60.00
62.50
72.50
80.00
85.00
95.00
Water pressure
kpa
58.00
58.00
67.00
72.00
72.00
72.00
72.00
72.00
72.00
73.00
Refrigerant
 Type
R22
kilogram
kg
64.00
75.00
80.00
89.00
96.00
99.00
114.00
127.00
136.00
152.00
Safety protection
High and low pressure protection; high and low pressure protection; over temperature protection; overload protection ,over temperature protection, phase sequence protection, etc
Dimensions (L*W*H)
 Length
mm
3225
3225
3225
3505
3605
3605
3720
3720
3720
3930
Width
mm
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
 High
mm
1830
1830
1880
1880
1950
1980
1880
1950
1970
2020
Net Weight
kg
1970
2190
2440
2480
2650
2950
3080
3300
3470
3620
Operating weight
kg
2190
3380
2570
2740
2950
3210
3330
3570
3810
3930
1.Freezing water inlet temperature -10ºC, freezing water outlet temperature -15 ºC; cooling water inlet temperature of 30 ºC, cooling water outlet temperature of 35 ºC; Â
2.Temperature conditions: Freezing water outlet temperature range 5 ºC-15 ºC, cooling water inlet temperature range 19 -33 ºC;                                                                                                                                          Â
3.Safe operating range : Freezing water inlet temperature 9ºC-20ºC;                                                                                                                                                                                                                                                             Â
4.The using compressor is closed turbine  imported from Europe and the United States , superior performance, strong ability of anti-effusion;                                                                                                              Â
5.Nominal operating conditions in the evaporator and condenser water side fouling factor of 0.018m² ºC / kw, condenser water side fouling factor of 0.044 m² ºC / kw;                                                                               Â
6. Water side of the evaporator and condenser, designed to withstand a pressure of 1.0MPa;                                                                                                                                                                                                                        Â
7. The actual head of Host is that the pump head minus head losses within the host; Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â
8.In addition to the specifications and requirements, we can provide non-standard products according to customer requirements.
Â
Company profile:
Contact Way:
Model NO.: WD-195W
Application Fields: Food Processing
Application Machine: Machining Center
Certification: ISO, CE
Condition: New
Cooling Capacity: 30-1000usrt
Refrigerant Type: R22/R134A/R407c/R410A/R507/R404
Dimensions: 1200*700*1100mm
Total Weight: 2500kg
Trademark: winday
Transport Package: Wooden Case
Specification: CE, ISO9001
Origin: Shanghai
HS Code: 8418699090