Turbo Kit For K03,Audi Repair Kit,K03 Turbo Kit,Repair Kit Of Audi Fengcheng Fire Turbocharger Manufacturing Co; Ltd. , https://www.fireturboexpert.com
1.1. Labor protection products must be worn as required before operating the equipment;
1.2. The operator must be trained before taking up the post, and can only be post-qualified after passing the assessment.
Second, before the operation of equipment inspection
2.1. Complete the equipment check according to the inspection table to understand the equipment status and make corresponding records;
2.2. Check the status of the waterway and gas path before starting the system, whether the air pressure is normal, whether the valves are in the correct position, and there is no leakage of air leakage.
2.3. Before the work, check whether the concentration of the cleaning solution and the proportion of the formulation are appropriate according to the cleaning process, and whether the height of the liquid level in the tank is sufficient;
2.4 Check the oil level of the motor of the high pressure washer. It is forbidden to start the high pressure washer when the fuel tank is empty.
Third, equipment operation precautions
3.
4.
4.1. Cleaning agents and water softeners are chemicals. Do not touch other dangerous sources, such as splashing into the eyes or other parts of the body. Rinse quickly with water and go to hospital for treatment.
4.2, prohibit any part of the body into the movable parts area, such as: activity room ceiling, etc., if the pump is opened, the device housing can not be placed on the cup, beverage bottles and other items;
4.3. When lifting the mold from the outside to the cleaning platform, it must be ensured that the movable ceiling is in the fully open position. When the mold enters the cleaning room, it should be carefully observed to avoid damage to the mold or cleaning the house;
4.4. Regularly remove the oil in the slick tank according to the amount of cleaning;
4.5. In the automatic operation state, if the storage tank and the sump simultaneously show a low water level, the valve connected to the tap water network should be opened to replenish the entire system.
Fourth, the operating procedures
5.
5.1. Push the main power switch (on the left door of the control cabinet), rotate it to the “ON†position, the power indicator light is on, and the status indicators are normal;
5.2 After power on, in the absence of alarm, press the auto-run button, the green light on the control cabinet is on, the operator only needs to operate the cleaning machine, no other operation, the entire cleaning room system will automatically run;
5.3, open the cleaning room roof, hanging into the mold to be cleaned. When the roof is opened, the red light will flicker and a buzzer will sound. When the roof is fully opened, the red light will be on. When the roof is closed, the warning light will be steady green.
5.4, ​​open the cleaning room fan, lighting, according to the cleaning process to the cleaning machine to add cleaning fluid, softener, set the flush temperature, pressure. Press the washing machine handle flush button to flush the mold;
5.5. Blow dry and spray anti-rust oil according to the cleaning process;
After the end of the work day, close the cleaning roof, press the automatic stop button, and disconnect the electricity, gas, and water from the equipment.
First, the safe operation of the premise