Non-woven special equipment accessories
Non-woven fabric is a new type of modern material. It has a wide range of uses and can play more roles in clothing, agriculture and industry. The production of non-woven fabrics is also mostly mechanized, which makes it possible to produce a large number of non-woven fabrics in batches. Non-woven fabric winders are one of its equipment.
Non-woven fabric, also called non-woven fabric, is composed of oriented or random fibers. The production of non-woven fabrics often uses polypropylene pellets as raw materials, and is produced by a continuous one-step method of high-temperature melting, spinning, laying, and hot-pressing. In the production of non-woven fabrics, the raw materials need to be spun and formed and then processed. In the web-forming work, a non-woven web forming machine needs to be used. The web forming machine uses wind in the drafting duct to process the silk. After drafting, a machine for non-directional weaving into a net is carried out. However, polypropylene pellets are prone to broken filaments and stiff blocks during drawing, drafting, and web formation. Therefore, in order to improve the quality of the finished non-woven fabric, it is necessary to clean the formed non-woven fabric. When dealing with broken wires and stiff blocks in traditional web forming machines, workers usually use brushes or scouring pads behind the web forming machines to clean up. Because the belt width of the web forming machines is relatively long, and the conveyor belt speed is relatively high at the same time. Fast, the cleaning range that workers can cover is limited, resulting in low cleaning efficiency, which in turn affects the quality of the finished non-woven fabric.
The slitting machine is mainly used to cut large-format non-woven fabrics into multiple small non-woven fabrics of different widths for processing non-woven products. The equipment adopts DC speed regulation, feeding constant tension control, air knife slitting, rewinding pressure and other devices. The rewinding tightness after slitting is adjustable, and the slitting end surface is flat. The equipment is of high quality and beautiful appearance. It is the ideal equipment for the slitting of large non-woven fabrics. In addition, according to the needs of users, the equipment can also add a dummy cutting function, that is, the original fabric is dummy cut and then slit and rewinded.
Non-woven fabric machinery is a general term for the production of non-woven fabric products, and adopts an overall modular design with a compact and reasonable structure. The control part adopts advanced PLC microcomputer control, and the international famous brand frequency converter speed regulation.
Melt blown mold head, Cross forming machine, slitting machine, Non woven fabric winding machine, non-woven high-speed winding machine, non-woven high-speed web forming machine, Netting machine, polyester non-woven fabric sizing and drying equipment Changzhou Puyisen Machinery Technology Co., Ltd. , https://www.czsmmsmachine.com
Diesel generator sets also need a certain maintenance method in winter, so that the use of diesel generator sets will last for a long time.
The low temperature in the winter will make the viscosity of diesel oil increase and the fluidity will deteriorate. As a result, the diesel oil will not spray easily, causing poor atomization and even worse combustion. As a result, the dynamic and economic performance of the diesel engine will be reduced. Therefore, the freezing point should be low in winter. Good light diesel oil with good fire performance. General requirements for the freezing point of the diesel engine should be lower than the current local low temperature of 7-10 °C.
Second, start the fire with an open flame
Where the temperature is too low, an open flame can be used to help start the machine, but the air filter must not be removed. After being ignited with diesel oil, the firearms were placed into the air intake pipe to start combustion. In this way, during the start-up process, the external dust-laden air will be directly sucked into the cylinder without filtering, causing abnormal wear of pistons, cylinders and other parts, and can also cause the diesel engine to work rough and damage the machine.
Third, put the water prematurely or do not put the cooling water
The generator runs at idle speed before shutting down, until the cooling water temperature falls below 60°C, the water is not hot, and the water is turned off and discharged. If the cooling water is discharged prematurely, the body suddenly suffers sudden shrinkage and cracks when it is exposed to cold air. When the water is drained, the residual water in the body should be completely discharged to prevent the ice from expanding and the body can burst. Shunjin Xingdu hereby advises users that antifreeze fluids should be used no matter what season, and anti-freeze fluids must be used in high-end generator sets. Because antifreeze not only plays a cooling role, but also protects the diesel engine.
Fourth, the selection of lubricants
In winter, oil with a low freezing point should be used, and the temperature of the oil can be increased by using a method of warming the outside bath. It is not recommended to use an open flame so as not to deteriorate or even burn the oil in the oil pan. Lubrication performance is reduced or completely lost, thereby aggravating machine wear.
Fifth, start method
In the winter, it is conditional to equip the generator with a water jacket heater so that the machine can maintain a certain “body temperature†and can easily be operated at any time. Some operators are able to quickly start the diesel generator set, and often use the non-normal start method of waterless start (first start, then add cooling water). This practice can cause serious damage to the machine and should be prohibited. The correct method of preheating is as follows: first heat insulation is covered on the water tank, open the drain valve, and continuously inject 60-70°C clean soft water into the water tank, touch the water discharge valve with hand to feel hot, then close the drain valve, Then start again.
Six, low temperature with load considerations
After the diesel generator set fired, some operators could not wait to immediately put into load operation. In a diesel engine that is on fire soon, due to the low temperature of the engine body and the large viscosity of the engine oil, it is difficult for the engine oil to fill the moving friction surface and cause serious machine wear. In addition, plunger springs, valve springs, and injectors
Previous:Common faults of AC motors and their causes
Diesel generator set winter maintenance method diesel generator | diesel generator price / 2017-11-27