Model NO.: GD-2100
Chemical Analysis Type: Karl Fischer Method
Operating Mode: Touch Screen
Heating Mode: Standard Heating
Off Mode: Manual
Item Name: ASTM D6307 Columetric Karl Fischer Titrator
Function: Determine Water Content in Oil, Liquid, etc.
Application Field: Petroleum, Chemicals, Pharmacy, Electricity, etc.
Measurement Range: 3ppm to 100%
Test Standards: ASTM D6307
Advantages: High Accuracy, Good Repeatability, Low Cost
Packing Size: 56*37*39cm
Gross Weight: 13kg
Power Supply: 220V, 50Hz
Warranty Period: 1 Year
Trademark: GOLD
Transport Package: Packed in Veneer Case
Specification: 320 * 240 * 180mm, 6kg
Origin: Chongqing, China
HS Code: 9031809090
GD-2100 Automatic High Senstive ASTM D6307 Columetric Karl Fischer Titrator
 
Introduction: 
GD-2100 Automatic High Senstive ASTM D6307 Columetric Karl Fischer Titrator adopts Karl Fischer Coulometric method.
GD-2100 Automatic High Senstive ASTM D6307 Columetric Karl Fischer Titrator owns advantages of high testing accuracy, good repeatability, low testing cost etc.
GD-2100 Automatic High Senstive ASTM D6307 Columetric Karl Fischer Titrator is used to accurately test trace water content in various liquid, solid and gases.
And it is widely applied to petroleum, chemical engineering, pharmacy, electricity, scientific research, education department and so on.


Specifications:
No. Item Name GD-2100 Automatic High Senstive ASTM D6307 Columetric Karl Fischer Titrator
1 Measuring range 3ug to 200 mg water
2 Water content range 3ppm-100%
3 Resolution 0.01 ug water
4 Accuracy 10μg-1mg water, ± 0.2%; >1mg water, < ± 0.3%
5 Electrolysis speed max 2.4 mg/min
6 Electrolytic current 0 ~ 430 mA
7 Working environment 5 ~ 35 ºC; Humidity: ≤85%
8 Dimension&Weight 320 * 240 * 180mm, 6kg
9 Power supply AC 220V ± 10%


Features:

Intelligent Determination
Powerful new-generation processor; dual-CPU design.
Dual power channels separate electrolytic electrode and measuring electrode; automatically removing all kinds of interference; greatly improving the accuracy of test results.
Measuring electrode data directly A / D sample converting; data true value avoids errors caused by analog circuit; results more accurate.
 
Easy Operation
Touch-screen operation; only pressing once then the test will be done automatically and the reported values will automatically display.
 
Background Compensation
Large current background compensation. Standby time can be shortened to be less than 10 minutes.
 
Rotating Speed Control
Software adjusting stirring speed; selection between 0 to 36.
 
End Point Indication
Character tips and buzzer
 
Perfect Calculating Function
Automatically display, calculate, print ug / ppm / percentages / mg/L / sample name / test date etc.
 
Automatic Date Storage
Year, month, day, hour, minute, second; automatic storage when power off.


Real Pictures:
Automatic High Senstive ASTM D6307 Columetric Karl Fischer Titrator

Our Service:
Presell Service:

Automatic High Senstive ASTM D6307 Columetric Karl Fischer Titrator

After-sale Service:
Automatic High Senstive ASTM D6307 Columetric Karl Fischer Titrator

Automatic High Senstive ASTM D6307 Columetric Karl Fischer Titrator

Electric Planer Blades

Electric Planer Blades ,Electric Hand Planer Blades,Electric Wood Planer Blades,Sharpening Electric Planer Blades

SICHUAN TELOS NEW MATERIAL TECHNOLOGY CO., LTD , https://www.telostool.com